XTEMOS ELEMENT
AJAX PRODUCTS TABS
Bottle Stand for 6 bottles
Combined Object and Receiving Screen
Digital Viscometer
Description
Digital Viscometer Ensuring proper fluid viscosity is key in process environments. Achieving this requires an accurate, reliable, and durable in-line viscometer capable of monitoring fluid viscosity with minimal operator involvement. The Cambridge Viscosity VISCOpro 1600 viscometer is an ideal digital viscometer for this application due to its high accuracy and reliability, as well as its inherent ruggedness. The VISCOpro1600 viscometer can be used alone or in a multi-channel configuration controlled by a touch-screen display. This digital viscometer provides continual viscosity monitoring you can rely on. It is a compact instrument for applications where minimal operator involvement is desired. This digital viscometer features an optional LCD display for monitoring of critical fluid conditions. It also can be connected to a programmable logic controller (PLC) for seamless integration into a proprietary data management system. The units sensor and electronics are encased in an explosion-proof housing for durability and reliability. Due to Cambridge Viscositys patented technology, only a very small amount of fluid (1 ml) is required to obtain an accurate reading. Due to the small sample size needed and its automatic operation, the VISCOpro 1600 helps to maximize the efficiency of your process line and minimize waste. In addition, it works with most Cambridge Viscosity in-tank or in-line 300 series or 500 series sensors, giving you the flexibility to choose from a range of high-quality, maintenance-free options.Ray box Multi Slit
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Refrigeration Trainer Electrolux Type
This type of refrigeration is usually used for domestic purposes only as it is complex in the construction and working. This type of refrigerator was developed in 1925 by Munters and Battzervan when they were studying at Royal Institute of Technology At Stockholm for their undergraduate course. This type of refrigerator was known as three fluid refrigeration system. The elimination of aqua pump from the absorption system with the complete absence of moving parts and work input. The main purpose of removing the pump was to make the machine noiseless. It uses refrigerant as a solvent s and an inlet gas for inlet of the system. The inert gas is continued to the lower side of system only by its system. It is possible to maintain the uniform pressure throughout the system and after sometime permitting the refrigerant to evaporator at low temperature corresponding to its partial pressure. In the high pressure side system (generator and condenser), there exists only the refrigerant which is subjected to total pressure of the system so that it is condensed by using normal cooling water as air as it is done in other system.
The strong aqua ammonia solution is heated in generator by the application of external heat source. The water vapor carried with ammonia vapor is removed in separate form as shown in figure. Then the dry ammonia vapor is passed into the condenser and it is condensed by using external cooling source. The liquid ammonia flows under gravity in the evaporator and it evaporates. The mixture of hydrogen and ammonia vapor is passed into the absorber and the weak solution from aqua ammonia from the separator is allowed to follow into the absorber, through tray this weak aqua ammonia solution comes into contact with hydrogen separated. This strong solution is further passed to the generator and it completes the cycle.
Human Reproduction Charts
Description
Poly art Charts are multi colored, accurate in details, printed on plastic, laminated on both sides, washable, non-tearable and long lasting with plastic rollers, size 75 x 100 cm. Human embryological development. Human Life cycle (birth). Human reproductive organs, male. Human reproductive organs, female.Demonstration Meter
Diffraction Object Holder
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Water Cooler Trainer
The apparatus consists of a storage water tank, embraced by evaporator coil of the cooling unit, cooling cycle comprises of a hermetically sealed compressor, air-cooled condenser, a capillary tube as expansion device and an evaporator cell. The stainless steel water tank is provided with insulation on air Sides and a door are provided at the top. Cold water can be taken out from a top provided and inlet water supply is controlled by a bail-operated top. Various measurements provided enable students to determine the theoretical and actual COP, power consumption, actual cooling capacity refrigerant flow and compressor volumetric efficiency of compressor.
SPECIFICATIONS:
Cooling Cycle a) Compressor Hermetically sealed type, having the capacity of 1/3 ton of refrigeration using R-12 refrigerant. b) Finned tube type air colled condenser with forced air flow. c) Filter cum drier for refrigerant. d) Capacity expansion device. e) Evaporator coil embraced on stainless steel water tank, Provided with glass wool Insulation. 2.Water drain tap and float operated inlet water tap are provided for water tank with insulated lift door at top. 3.Measurement a) Pressure gauges for evaporating and condensing pressure. b) Thermometers to measure refrigerant temperatures at inlet and out let of condenser and evaporator. c) Dial type thermometer for water temperature. d) Rotameter to measure liquid refrigerant flow. e) Energymeter to measure compressor Input. 4.Safely & Controls – a) Thermostat to put off compressor at set water temperature. b) Pressostat to put off compressor if high or low pressure Goes out of set limit. c) Over load protector for compressor, A technical manual will be supplied along – with the unit. Also, the unit is provided with an attractive and anti corrosion powder costing.SERVICES REQUIRED:
1.Floor space of 1.5 m. X 1.5 m. 2.Water supply of 5 lit/min, 3.230 V, 15A AC stabilized supply with earthing connectionVortex Shaker (Test Tube Shaker)
Compact Vortex Shaker
Compact, rugged construction. Heavy metal base & rubber feet prevent movement of the shaker during use. Choice of continuous & touch mode. Variable speed control. Include one hand insert, micro tube insert & cup attachment.Product Details
Maximum speed : 3000 rpm Usage : Laboratory Capacity : 600mlCryovial
Cryovial are normally used for storage of Biological material, human & animal cells.
These sterilized tubes are provided with white prominent graduation and a long marking area for sample identification.
The cap of these Cryovial is provided with a seal ring inside to make it completely leak proof.
The longitudinal grooves in the base give a non-twisting feature to these vials when paced in a cryo rack.
Material : Polypropylene
Particulars | Pack (Pcs) | |
---|---|---|
Cryo Vail - Internal Thread 2.0 ml | 500 | |
Cryo Vail 1.8 ml | 1000 | |
Cryo Vail 4.5 ml | 500 |
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Displacement Vessel, Glass
CNC Lathe Trainer1
CONTROLLER:
Type of control system: PLC based system Main Spindle Drive : AC Motor with VFD Z and X Drives : Stepper drive with RAMP function Input to Stepper Motor : Optically Isolated Motor Drive :TTL Compatible Run Speed Control : Computer controlled through software Interpolation : Linear / Circular / Parabolic Cycles Used :G,M,S,T,F,I,K,M,F Cycles : Circular Interpolation / Canned Threading : Straight / Taper Power Devices : Short Circuits and over Temperature Protected Real Time Tool Path Simulation : ProvidedMACHINE DETAILS:
Center height : 100mm Swing over Carriage : 80mm Distance between Centre : 250mm Longitudinal Travel : 250mm Weight : 350 kg Dimension in mm : 1100 x 750 x 1700 Rapid Travel : 500mm/min Resolution X & Z Axis : 10micron Dt. Motor Power : 40V – 4A Lubrication : ManualSPINDLE:
Spindle Speed : Continuous Variable Spindle Power : 1.5 HP Inside Taper : MT3 Speed Range : 100 to 3000 RPMRefrigeration Test Rig
Features
• 5 Nos of thermocouples are provided to measure the temperature at different points. • One multi channel temperature indicator is provided to display the temperature • One capillary tube and one thermo expansion valve is provided to check the performance separately. • Compressor supplies refrigerant through evaporator to find out cooling effect • 4 Nos. of Pressure Gauges are provided to measure the pressure at various point • One Energy meter is proivded to measure the overall power consumption • One voltmeter is provided to display the voltage. • One ammeter is provided to display the current.Specification
• Compressor :Hermatic • Capacity : 1/4 Ton • Supply : 230 V AC / 50 Hz • Condensor : 12 Coil • Evaporator : 15 Liter Capacity • Refrigerant : R134AXTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Episiotomy Training Simulator
Description
Suturing Simulators provide a realistic way for students to learn good surgical techniques. The simulators provide students with a variety of repair experiences without the constraint of time and concern for safety, which are factors with a live patient. The simulators can be used by the student in a learning lab with an instructor or by the student individually in the clinical setting just prior to a patient experience. They are also useful as homework teaching aids that can be signed out at night and returned the next day. In addition to being portable, the lifelike texture allows the learner to develop a “feel” for instrument handling, tension on suture, and the advantages of one method of tying knots over another.Includes one of each simulator:
Midline Suture Simulator Left Mediolateral Suture Simulator Right Mediolateral Suture Simulator Each simulator comes with an instruction booklet and is individually boxed.RF Telemetry
RF telemetry system consists of a radio frequency transmitter and matching radio frequency receiver both operating at 433 MHz. The system is designed for the radio frequency transmission and reception. The radio frequency transmitter sends out a variable audio signal and the radio frequency receiver with built in loud speaker receives the signal. The system enables the teachers to demonstrate a variety of wave phenomenon. The system also enables the properties of the radio communications to be investigated and compared with those of visible light and other wave motions such as audible sound and water waves etc. For the operation of the system, a 9 V PP3 battery is required.
Motor Generator Model Set
Description
This motor-generator set gives students an insight into the physical and technical relationships on which electric motors, generators and transformers are based. The modular system allows to set up different function models without tools: Various DC motors Series and shunt motor Synchronous motor DC generator and alternator Transformer. This set allows the performance of 10 student experiments about the following topics: Magnetic field of a coil Conversion of electrical energy into kinetic energy Commutator Direct current motor Synchronous motor Series and shunt-wound motors Electromagnetic induction The electrical generator Engine-generator TransformerXTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT