XTEMOS ELEMENT
AJAX PRODUCTS TABS
Hand Microtome
Description
A handy and simple model with wide flat top, suitable for sectioning of fresh tissues. Screw drum is graduated in 100 close divisions and will cut the specimen in steps of 10 microns each. Complete with a single edged razor blade. But with differential screw, screw drum is graduated in 50 wide divisions.Optical Auto Engineers Level
Features
• Excellent shockproof function. • Exclusive closed magnetic field, magnetically-dampened compensator. • Friction-braked rotation and endless horizontal drive. • Prism for viewing circular vial. • Water, dust and dirt proof. • Comes with a years warranty. • Full back up and repair service available.Displacement Vessel, Glass
Magnifier, Folding
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Laboratory Spatula
Acquire from us high quality Laboratory Spatula at affordable price range.
Moulded in Polypropylene, Spatula consists of a spoon on one side while the other end is a flat construction with a knife edge.
This is helpful in breaking up crystals of different salts while the spoon is used to draw salts from the containers.
Particulars | Pack (Pcs) | |
---|---|---|
Spatula 150 mm | 12 | |
Spatula 200 mm | 12 |
Insect Cage, Round Shape (Acrylic)
Electric Motor, Demonstration
Volumetric Flask
We introduce our special quality Volumetric Flasks.
These Volumetric Flasks are blown in Polypropylene and are strong, unbreakable and have good contact clarity.
These autoclavable Volumetric Flasks are provided with screw caps to prevent leakage.
These Volumetric Flasks are economic as well.
Material : Polypropylene
Particulars | Pack (Pcs) | |
---|---|---|
Volumetric Flask 25 ml | 6 | |
Volumetric Flask 50 ml | 6 | |
Volumetric Flask 100 ml | 6 | |
Volumetric Flask 250 ml | 3 | |
Volumetric Flask 500 ml | 3 | |
Volumetric Flask 1000 ml | 2 |
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Demonstration Meter Inter Scale
Description
Housed in a ABS plastic case 300x150x300 mm with glass front and rear. Moving coil type with accuracy of + 2.5%. Basic sensitivity of meter is 5 mA, 100mV f.s.d. The meter can be used to demonstrate the working principle of AC or DC ammeters or voltmeters with the interchangeable plastic scales. DIFFERENT DIALS ARE AVAILABLE.Human Head And Neck L. S.
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Frequency Response Analysis of Lead Lag Network
Frequency response of Lead, Lag network using P+I+D controller is a special purpose analog simulation, create using operational amplifiers. This simulator permits a detailed analysis of the first order and second order systems on the application of proportional, integral and derivative control to the improvement of their performance. The simulator may be used at high frequency for oscilloscope observation.
FEATURES:
• Built-in Function Generator (sine & square). • Self contained power supplies and power ON/OFF switch with indication. • Full mimic diagrams in the front panel. • The simulated process. - Simple Lag Process - Simple Lead Process • The simulated PID controller - Integral controller scaled in Integration time. - Derivative controller scaled in derivative action time. - Proportional band control scaled in % proportional band (PB).3Ø – 3Ø Matrix Converter
FEATURES:
• 9 No. Bi-directional Switch with IGBT and Fast Diode Bridge,Rating@1200V 50A Forms 3 Phase to 3 phase Matrix Converter Power Circuit • Output of Matrix Converter Terminated by Banana Connector in the Front Panel • 9 No. High Speed Opto- IC Provided for Gate PWM Isolation. • 9 No. Single Channel IGBT Driver IC with Current Limiting Facility Provided for IGBT Gate Driving. • 9 No. 15V DC Power Supply Provided Internally for Control Circuit. • 3 No. Inductor and AC Capacitor Provided for Three Phase Input Filter. • One No Three Phase Synchronizing Transformer (230/9V) Provided for three Phase Supply Synchronization • 6 nos Hall-effect Current Sensor with Signal Conditioning Circuit Provided for Output and Input Current Measurement and Protection. • AC voltmeter is provided for measure the input AC voltage. • +/- 15V DC Internally Provided for Sensor Signal Conditioner Circuits. • MCB Provided for Input power ON/OFF and OL Protection ON/OFF Switch. • Test points are provided on the front panel to measure the voltage, current and PWM signals • 34 pin FRC Connector Provided for IGBT Gate PWM Inputs. • Input : Three Phase 440V AC, 50 Hz. • Output : Three Phase Variable Voltage, variable frequency • Rating : Suitable for 1 HP 3Ø AC Induction MotorDisplacement Vessel, Glass
Friction Board
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
CNC Lathe Trainer1
CONTROLLER:
Type of control system: PLC based system Main Spindle Drive : AC Motor with VFD Z and X Drives : Stepper drive with RAMP function Input to Stepper Motor : Optically Isolated Motor Drive :TTL Compatible Run Speed Control : Computer controlled through software Interpolation : Linear / Circular / Parabolic Cycles Used :G,M,S,T,F,I,K,M,F Cycles : Circular Interpolation / Canned Threading : Straight / Taper Power Devices : Short Circuits and over Temperature Protected Real Time Tool Path Simulation : ProvidedMACHINE DETAILS:
Center height : 100mm Swing over Carriage : 80mm Distance between Centre : 250mm Longitudinal Travel : 250mm Weight : 350 kg Dimension in mm : 1100 x 750 x 1700 Rapid Travel : 500mm/min Resolution X & Z Axis : 10micron Dt. Motor Power : 40V – 4A Lubrication : ManualSPINDLE:
Spindle Speed : Continuous Variable Spindle Power : 1.5 HP Inside Taper : MT3 Speed Range : 100 to 3000 RPMTrapezoidal Prism, Acrylic
Malu’s Law
Description
Students can investigate the relationship between the intensity of transmitted light and the angle of rotation of two polarizing filters. A graduated cartridge containing two polarizing filters allows students to observe the change in intensity as they are rotated relative to one another. The analyzer allows quantitative readings to be taken using a voltmeter at five degree intervals as the polarizing filters are rotated from minimum to maximum transmission. The output from the analyzer changes linearly with light intensity and so the resulting data can be used to verify Malus Law. Includes instructions.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT