AJAX PRODUCTS TABS
Car Air Conditioning Actual Cut Section
Plates For Simple Cell
Advanced Stereo Zoom Microscope
Specifications
Advanced Stereo Zoom Microscopes provides reliable mechanical components and best quality optics. This exceptional quality instrument helps the users to perform certain tasks efficiently and maintaining high productivity. The wide variety illuminators and stands are provided with the instrument to suit the requirement of different applications. These microscopic instruments provides the zoom magnification from 8X to 50X. The Zoom ratio 6.3:1 with standard eyepiece Wide Fiels 10X/22. The images are clear, sharp, flat and high-resolution contrast even at the edge of field. This exceptional quality instrument helps the users to perform certain tasks efficiently and maintaining high productivity.
The images are clear, sharp, flat and high-resolution contrast even at the edge of field. It is the best instrument which best suited for biological research as well as in industrial laboratories where large field coverage, maximum working distance and high precision is required. The Binocular Body of the device is inclined at 45o for fatigue free viewing that can be rotated complete 360o and that can be locked in any position. The Instrument has Ergonomically design bilateral ocular tubes that can be interlocked for enhanced operations. The instrument is equipped with incident lights that are build in the stand. The lamps can be switched on either separately or together with the LED.Multi Tank System
Panel Features
• Rocker switch is provided to ON/OFF the process plant. • Digital Panel Meter. • Pump Indicator. • Short Circuit protection. • Mimic diagram in the panel. • All the electrical connectors are terminated in the panel.Features
• This equipment consists of four tank system, conical tank system and spherical tank system. • Four numbers of Acrylic tank are provided for doing multivariable control of four tank system. • Conical tank (SS) is provided to performing the nonlinerar control system. • Spherical tank (SS) is provided for controlling the complex system. • Six numbers of level transmitter (DPT) are provided to measures the level of the each tank. • Three numbers of smart control valve with positioner are provided in the inlet of Flow rate. • Hand valve is provided at the bottom of the process tank to study the load disturbance. • Three numbers of hand valve are provided to control the Rotameter flow rate. • Three numbers of centrifugal pump are provided for water circulation. • Two flow transmitters are mounted for conducting flow, cascade and Ratio control. • Appropriate Digital panel meters are provided to measure the transmitter and actuator signals. • Delay coils are provided to the input of the process tanks for transportation lag study. • Storage tank of 100 litre capacity (SS). • Rotameter for Visual indication of the flow rate. • Relay circuit is provided to ON/OFF the solenoid valve. • Built in regulated power supply. • All Water flow lines are connected by (SS) fittings. • Necessary patch chords are provided for interfacing the Electrical signal. • Established successful design that mimics a real industrial process. • Front panel includes mimic diagram of the process, so students can clearly see what they are controlling. • Safe, practical and realistic. • Hand valves are provided to study the coupling (Interaction) and decouplingAJAX PRODUCTS TABS SIMPLE

Male Catheterization Training Simulator
Description
Catheterization Trainer Simulator trainer, male bladder catheterization procedures can be realistically demonstrated, practiced and assessed. The genital inserts are placed into the anatomically correct lower abdominal model and held in place with magnets.The material is soft and flexible:
the foreskin is movable and the penis can be stretched. This way the student can practice all the necessary gestures for catheterization (e.g. disinfection). The material gives a realistic feeling when inserting and removing the catheter into the bladder with realistic resistance and insertion depths.Direct learning:
When the catheter has been correctly inserted, fluid runs out, just like with a real patient. The catheter can also be checked through the transparent bladder. The abdominal wall can be removed so that the process can be viewed better.Various levels of difficulty:
On the male insert, three different levels of prostate narrowing can be set. In the narrowest case, the student can feel that catheterization is no longer possible through the urethra and that a suprapubic catheter will have to be inserted. A suprapubic catheter has already been put in place and the student can practice cleaning it and taking care of it with the trainer.All the benefits of the male catheterization simulator at a glance:
Male catheterization with realistic resistance 3 levels of adjustable prostate narrowing soft and movable foreskin (for practicing disinfection, for example) Anatomically realistic pelvic structure Liquid outflow if catheterization is successfully carried out The transparent bladder can be checked and the abdominal wall can be removed Includes suprapubic catheter for practicing, cleaning and caring for it. Stands securely on the table thanks to the non-slip feet Magnetic connectors for quick set-up and dismantling Easy to clean and maintain, and can be completely taken apart A sponge on the inside prevents a build-up of moisture.Reynold S Apparatus
DESCRIPTION:-
The Set-up is designed to verify Reynold’s Apparatus experimentally. The Apparatus consists of a glass tube which one end having bell mouth entrance connected to a water tank. At the other end of the glass tube a cock is provided to vary the rate of flow. Flow rate of water can be measured with the help of Measuring Cylinder and Stop Watch, supplied with the set-up. A capillary tube is introduced centrally in the bell mouth. To this tube dye is fed from a small container, placed at the top of Constant head Tank, through polythene tubing.EXPERIMENTS:-
Ø To study different types of flow. Ø To determine the Reynold’s Number and hence the type of floe either laminar or turbulent.UTILITIES REQUIRED: -
Ø Water Supply. Ø DrainTECHNICAL SPECIFICATION: - | ||
Ø Tube | : | Material Borosilicate Glass |
Ø Dye Vessel | : | Material SS, Suitable Capacity |
Ø Capillary Tube | : | Material Copper/Stainless Steel |
Ø Constant Head Water Tank | : | Capacity 40 Liters. |
Ø Water Circulation | : | FHP Pump |
Ø Flow Measurement | : | Using Measuring Cylinder |
Ø Sump Tank | : | Capacity 60 Liters |
Ø Stop Watch | : | Capacity 60 Liters. Electronic |
Ø Control Panel Comprises of | : | Standard make, On/Off Switch, Mains Indicator, etc. |
Ø The Whole set-up is well designed and arranged in a good quality painted structure. |
Aluminium Tripod Stand Dual Lock
Description
We are supply and Export of aluminum tripod stands that are procured from the trustworthy sources, who make these using high quality raw material such as brass and aluminum. These products are also available in a powder coated finish and are especially developed for providing maximum stability and strength. Moreover, all our products are available in various sizes, shapes and designs to fulfill the diverse needs of our clients.AJAX PRODUCTS TABS ALTERNATIVE
PC Cryo Box
Particulars | Pack (Pcs) | |
---|---|---|
Cryo Box (P.C) - 50 places for 1 ml or 1.8 ml cryo vails | 8 | |
Cryo Box (P.C) - 81 places for 1 ml or 1.8 ml cryo vails | 4 | |
Cryo Box (P.C) - 81 places for 4.5 ml cryo vails | 4 | |
Cryo Box (P.C) - 100 places for 1 ml or 1.8 ml cryo vails | 4 |
francis turbine test setup
DESCRIPTION:
Francis Turbine is a reaction Turbine, which was developed by English born American Engineer Sir J.B. Francis. The water enters the turbine through the outer periphery of the runner in the radial direction and leaves the runner in axial direction and hence it is called a mixed flow turbine. As the water flows to the runner, a part of pressure energy goes on changing into kinetic energy. Thus the water through the runner is under pressure. The runner is completely enclosed in an air tight casing and the casing & runner is always full of water. The present Set-up consists of a runner. The water is fed to the turbine by Means of centrifugal Pump, radially to the runner. The runner is directly mounted on one end of a central SS shaft and other end is connected to a brake arrangement. The circular window of the turbine casing is provided with a transparent. The circular window of the turbine casing is provided with a transparent acrylic sheet for observation of flow on to the runner. The runner assembly is supported by thick cast iron pedestal. Load is applied to the turbine with the help of brake arrangement so that the efficiency of the turbine can be calculated. A draught tube is fitted on the outlet of the turbine. The Set-up is complete with guide mechanism. Pressure and vacuum Gauge are fitted at the Inlet and Outlet of the turbine to measure the total supply head on the turbine.UTILITIES REQUIRED:
● Water Supply and Drain.● Electricity 15 kW, 440V Ac, Three Phase
TECHNICAL SPECIFICATIONS:
MODEL | HM 101 (1.33 HP) | HM 101 (2 HP) | HM 101 (5 HP) |
Output Power | 1.33 HP / 1 Kw | 2 HP / 1 Kw | 5 HP / 3.75 Kw |
Discharge | 1000 LPM (Approx.) | 1000 LPM (Approx.) | 2000 LPM (Approx.) |
Supply Head | 10 m | 10 m | 15 m |
Rope Brake Dynamometer | Dia 200 mm | Dia 200 mm | Dia 300 mm |
Sump Tank | Capacity 300 Ltrs. | Capacity 300 Ltrs. | Capacity 600 Ltrs. |
Water Circulation Centrifugal Pump | Capacity 5 HP, Three Phase | Capacity 5 HP, Three Phase | Capacity 15 HP, Three Phase |
Speed | 1500 RPM (approx.) | ||
Runner | Having Curved Vanes | ||
Discharge Measurement | Pitot Tube with Manometer | ||
Control Panel | Star/Delta Starter, Mains Indicator, MCB for overload protection | ||
The whole set-up is well designed and arranged in a good quality painted structure. |
AJAX PRODUCTS TABS ARROWS PAGINATION

Male Catheterization Training Simulator
Description
Catheterization Trainer Simulator trainer, male bladder catheterization procedures can be realistically demonstrated, practiced and assessed. The genital inserts are placed into the anatomically correct lower abdominal model and held in place with magnets.The material is soft and flexible:
the foreskin is movable and the penis can be stretched. This way the student can practice all the necessary gestures for catheterization (e.g. disinfection). The material gives a realistic feeling when inserting and removing the catheter into the bladder with realistic resistance and insertion depths.Direct learning:
When the catheter has been correctly inserted, fluid runs out, just like with a real patient. The catheter can also be checked through the transparent bladder. The abdominal wall can be removed so that the process can be viewed better.Various levels of difficulty:
On the male insert, three different levels of prostate narrowing can be set. In the narrowest case, the student can feel that catheterization is no longer possible through the urethra and that a suprapubic catheter will have to be inserted. A suprapubic catheter has already been put in place and the student can practice cleaning it and taking care of it with the trainer.All the benefits of the male catheterization simulator at a glance:
Male catheterization with realistic resistance 3 levels of adjustable prostate narrowing soft and movable foreskin (for practicing disinfection, for example) Anatomically realistic pelvic structure Liquid outflow if catheterization is successfully carried out The transparent bladder can be checked and the abdominal wall can be removed Includes suprapubic catheter for practicing, cleaning and caring for it. Stands securely on the table thanks to the non-slip feet Magnetic connectors for quick set-up and dismantling Easy to clean and maintain, and can be completely taken apart A sponge on the inside prevents a build-up of moisture.Microcontroller Based Differential Relay
Specification
• One PIC Microcontroller used as processor to read all current, (PY, SY) & activation of relay function • One LCD to indicate, - Set value, All currents - Set time, DMT/IDMT type - Relay tripping time. - Biased/Unbiased type status • Four numbers of key used - To select IDMT/DMT type or biased un-biased type - Set current value adjustment - Set time adjustment - Reset function • Six 5A CT used to sense primary and secondary current. • One 12V TPTT auxiliary relay used for contactor operation. • Specification: - Current input : 0-5Amp - Voltage input : 0-230V - Number of contact : Three number No contact @ 220V, 10Amp rating. - Auxiliary supply : 230VAC, 50Hz • PC interfacing facility power ON/OFF switch with indicator. • Make : VI MICRO • Model : VPL - 83AInvestigation With Mirrors Kit
Description
To Conduct basic experiments on the reflection of light from flat mirrors. The kit shows how adjacent mirrors reflect multiple images and demonstrates the principles of the periscope and kaleidoscope. The unit contains all the materials for the construction of a periscope and a kaleidoscope, including two sets of mirrors, mirror supports, and tubes. With instructions for assembly activity guide.AJAX PRODUCTS TABS WITH ICONS
Pipette Stand, Wooden – Horizontal
Plant Mitosis
Burner Bunsen – Teclu, LPG
Description
Burner giving a very hot flame, suitable for glasswork and soldering. A needle valve for fine flame adjustment is incorporated die casted base together with a tapered riffled tube connector. A unique spring operated gas safety lock is incorporated of the air/gas mixture. For use on natural gas supplies. Base dia. 80 mm and inlet tube 10 mm dia.Burner Specifications :
Tube Dia. - 13 mm Height - 150 mm Weight - 330 gLeopold Maneuvers Simulator
Description
One piece fetal baby with palpable fontanelles, spine, shoulders, elbows, and knees Fetal baby may be placed in normal, breech, or transverse position Fetal baby cradled between two “cushions” Cushions may be inflated independently of the other; inflation of the lower cushion raises the fetus to desired position; inflation of the upper cushion creates a firm abdomen as in the ninth month of pregnancy The Palpation Module is designed to be used with the Advanced Childbirth Simulator.AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML